White-Rodgers
White-Rodgers - 50D50-801 - Proven Pilot Spark Control Kit Replaces LENNOX 30W33
Item: WR50D50801
MFG: 50D50-801
loading availability
Loading price
Description
50D50-801 PROVEN PILOT SPARK CONTROL KIT REPLACES LENNOX 30W33
Non-Integrated Module Microprocessor Based Gas Ignition and Primary Safety Control Designed for Interrupted Spark and Burner Supervision of All Gases Used in Gas Fired Appliance Applications
FEATURES
SPECIFICATIONS
ELECTRICAL RATINGS:
Input Voltage: 18 to 30 VAC, 60 Hz
Current: 0.2A + MV + PV @ 25OC
Relay Contact Ratings:
Pilot Valve Relay: 1.5A @ 25 VAC, 60 Hz
Main Valve Relay: 1.5A @ 25 VAC, 60 Hz
Spark Output:
Gap: 0.1" - 0.2", 15 kV, 25Hz
Max cable length 3 ft (0.9 m)
Flame Current Requirements:
Minimum current to insure flame detection: 2 µA DC*
Maximum current for non-detection: 0.2 µA DC
Maximum allowable leakage resistance: 100 M ohms
* Measured with a DC microammeter in series with the flame probe lead
OPERATING TEMPERATURE RANGE:
-40° to 175°F (-40° to 80°C)
HUMIDITY RANGE:
To 95% relative humidity (non-condensing)
AGENCY APPROVALS:
CSA USA / Canada
GASES APPROVED: Natural, Manufactured, Mixed, Liquid Petroleum, and LP Gas Air Mixtures
Replaces: R47582-001, 94W83, 81W11, 81W03, 80M2701, 78M4701, 78M1701, 75M1701, 74W03, 56W19, 56L8501, 50A55-120, 17W70, 12L4201, 1195-83-100A, 1195-100, 103098-01, 103085-01, 103085-02, 103085-03, 1012-969A, 1012-977A, 1012-967, 1012-968, 1012-969,, 1012-83-9673A, 100973-01, 100973-02
Non-Integrated Module Microprocessor Based Gas Ignition and Primary Safety Control Designed for Interrupted Spark and Burner Supervision of All Gases Used in Gas Fired Appliance Applications
FEATURES
- Field service replacement for most Honeywell, Robertshaw, and Johnson Controls Intermittent Pilot Ignition Controls used on Lennox G20, G20R, G23 and G26 furnaces.
- Kit includes mounting bracket, flame sensor, and all other needed parts.
- Color LED indicator for diagnostics.
- Intermittent/Proven Pilot Spark Ignition
- Direct and Indirect Flame Sense
- Diagnostic LED
- Mounts Using Supplied Bracket in OEM Location
- Agency Approved
- All Required Conversion Accessories Included
SPECIFICATIONS
ELECTRICAL RATINGS:
Input Voltage: 18 to 30 VAC, 60 Hz
Current: 0.2A + MV + PV @ 25OC
Relay Contact Ratings:
Pilot Valve Relay: 1.5A @ 25 VAC, 60 Hz
Main Valve Relay: 1.5A @ 25 VAC, 60 Hz
Spark Output:
Gap: 0.1" - 0.2", 15 kV, 25Hz
Max cable length 3 ft (0.9 m)
Flame Current Requirements:
Minimum current to insure flame detection: 2 µA DC*
Maximum current for non-detection: 0.2 µA DC
Maximum allowable leakage resistance: 100 M ohms
* Measured with a DC microammeter in series with the flame probe lead
OPERATING TEMPERATURE RANGE:
-40° to 175°F (-40° to 80°C)
HUMIDITY RANGE:
To 95% relative humidity (non-condensing)
AGENCY APPROVALS:
CSA USA / Canada
GASES APPROVED: Natural, Manufactured, Mixed, Liquid Petroleum, and LP Gas Air Mixtures
Replaces: R47582-001, 94W83, 81W11, 81W03, 80M2701, 78M4701, 78M1701, 75M1701, 74W03, 56W19, 56L8501, 50A55-120, 17W70, 12L4201, 1195-83-100A, 1195-100, 103098-01, 103085-01, 103085-02, 103085-03, 1012-969A, 1012-977A, 1012-967, 1012-968, 1012-969,, 1012-83-9673A, 100973-01, 100973-02
California residents: see Proposition 65 Warning
Features and Specification
Weight | 1.35 |
---|---|
Brand | White-Rodgers |
Cubic Measurement | 0.0679 |
Dimensional Weight | 1 |
EAN | 0786710553400 |
GTIN | 00786710553400 |
Height | 5.5 |
Length | 2.6 |
Package Height | 5.5 |
Package Length | 2.6 |
Package Weight | 1.35 |
Package Width | 7.9 |
Prop 65 | Yes |
UOM | EA |
UPC | 786710553400 |
Width | 7.9 |
Country of Origin | MEX |