Ultra-Aire - 4036400 - Ultra-Aire 120V Whole House Ventilating Dehumidifier

Item: 4036400
MFG: 4036400
loading availability
Loading price
/ EA

Description

Recommended Installations Dedicated Ultra-Aire Return to HVAC Supply
  • Install a dedicated 10" air return for the Ultra-Aire 120V from a central area of the structure.
  • Install an insulated duct from outside to the 6" damper of the Ultra-Aire 120V to provide fresh air ventilation (optional).
  • When using only one of the two supplies on the Ultra-Aire 120V, the unused supply must be blocked using the duct cover plate included.
  • The optional second supply of the Ultra-Aire 120V may be ducted to another location. This can provide a second source of airflow to the basement or supply of the existing HVAC system with a backdraft damper.
  • If the existing system has multiple returns, instead of installing a dedicated return to the Ultra-Aire 120V, it is possible to select one to disconnect from the existing HVAC system and use it for the dedicated Ultra-Aire 120V return. Select a return from a central location in the house that is always open to the rest of the structure.
  • DO NOT use a return from a room where doors are kept closed.
  • DO NOT locate return in a bathroom or kitchen.
  • Control should be located remotely from the dehumidifier and placed in a central location. Closet Installation - Central Return to HVAC Supply
  • Locate the dehumidifier under or next to the HVAC system as space allows. A passive vent or louver door is required to allow air to be pulled in from the living space.
  • No inlet duct is required. Air is pulled through the passive vent or louver door from the living space.
  • Install an insulated duct from outside to the 6" collar of the Ultra-Aire 120V to provide fresh air ventilation (optional).
  • Duct the supply of the Ultra-Aire 120V to the supply of the existing HVAC system with a backdraft damper.
  • Control should be located remotely from the dehumidifier and placed in a central location.

California residents: see Proposition 65 Warning

Features and Specification

Weight 145
Amps 5.8
Brand Santa-Fe
Capacity Gallons 15.5
Cubic Measurement 14.9484
Cycle/Hertz 60 Hz
Electrical Rating 115 VAC
Energy Star Rated No
Height 46.5
Length 22
Operating Temperature Range 9°F - 95°F Max (Inlet Air Temperature) 34°F - 135°F Max (Outside Cabinet)
Prop 65 Yes
UL Listed Yes
UL Recognized No
UOM EA
Voltage 115 VAC
Width 25.25
Country of Origin USA

Documents

picture_as_pdf consumer literature

picture_as_pdf installation instructions

picture_as_pdf specification sheet

picture_as_pdf warranty document

picture_as_pdf service manual