Tempstar
Tempstar - RGH150HDCA0AAT - 12.5 Ton Gas Heating/Electric Cooling Single Package Rooftop Unit R-410A
Item: RGH150HDCA0AAT
MFG: RGH150HDCA0AAT
Description
HIGH EFFICIENCY PACKAGE GAS HEATING/ELECTRIC COOLING,
R-410A SINGLE PACKAGE ROOFTOP 3 Thru 12.5 TONS (1 & 3-Phase)
Built to Last, Easy to Install and Service
R-410A SINGLE PACKAGE ROOFTOP 3 Thru 12.5 TONS (1 & 3-Phase)
Built to Last, Easy to Install and Service
- R-410A HFC refrigerant
- ASHRAE 90.1 energy compliant and Energy Star qualified
- Single-stage cooling capacity control on all 036-072 models
- Two-stage cooling capacity control on 090 -150 models.
- Rated in accordance with AHRI Standard 210/240 (036-060 sizes) and 340/360 (072-150 sizes)
- Designed in accordance with Underwriters’ Laboratories Standard 1995
- Listed by UL and UL, Canada or ETL, ETL Canada
- Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Gas efficiencies up to 82%
- Induced draft combustion
- Redundant gas valve, with 1 or 2 stages of heating Pre-painted exterior panels and primer-coated interior panels tested to 500 hours salt spray protection
- TXV refrigerant metering device on each circuit. Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic and energy saving indoor fan motor delay
- “Low NOx” models available that meet California Air Quality Management NOx requirements and include stainless steel heat exchangers
- Cooling operating range from 35 F up to 125 F. 110 size model standard cooling operation down to 0ºF (-18ºC)
- Access panels with easy grip handles and no-strip screw feature
- Two-inch disposable return air filters
- Tool-less filter access door
- Belt drive evaporator-fan motor and pulley combinations available on all three phase models
- Direct Drive x13 (5 speed/torque) motor on 036 to 060 models
- Advanced terminal board for simple safety circuit troubleshooting and control box arrangement
- Field convertible from vertical to horizontal airflow on all models. No special kit required on 036-120 models. Supply duct kit required for 150 size model only.
- Provisions for thru-the-bottom power entry capability Single point gas and electric connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
- Scroll compressors with internal line-break overload protection
- Copper tube, aluminum fin coils
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated evaporator-fan motor
- Permanently lubricated, totally enclosed, shaft down condenser motors
- Low pressure, freeze protection, and high pressure switches
- Exclusive IGC anti-cycle protection for gas heat operation
- Solid-state electronic direct spark ignition system
- Liquid line filter drier
- 15 Year limited warranty on optional stainless steel heat exchanger
- 10 Year limited warranty on aluminized heat exchanger
- 5 Year compressor limited warranty
- 1 Year parts limited warranty
California residents: see Proposition 65 Warning
Features and Specification
Weight | 1430.000000 |
---|---|
Product Family | RGH |
Prop 65 | Yes |
Refrigerant | R-410A |
Height | 57.375000 |
Length | 115.875000 |
Phase | Three |
Number of Fan Blades | 3 |
OPT Code | 1PRGH150HDCA0AAT |
UL Listed | Yes |
Sound Level (dBA) | 83 |
AHRI - Usage | Packaged |
Gas Connection Size | 3/4" [19.05 mm] N.P.T. |
Evaporator Coil Metering Device | TXV/TEV - Thermostatic Expansion Valve |
Stage | Two |
Thermal Efficiency | 80% |
Tonnage | 12.5 |
UOM | EA |
UPC | See Optical |
Voltage | 208-230 VAC |
Width | 63.375000 |
Heating Capacity | 15000-240000 |
Color | Gray |
CFM Cooling | 3750-6250 |
CFM Condenser Fan | 0 |
CBU - Compressor Bearing Unit | Yes |
Brand | Tempstar |
Blower Wheel | 18" x 18" |
Blower Motor Type | Belt Drive |
Blower Motor RPM | 440-609 |
Blower Motor HP | 2 9/10 HP |
Air Flow | Multi-Position |
Circuit Breaker - Max Amps | 80 |
Blower Motor Speeds | 2 (Two) |
Compressor | Scroll |
Condenser Motor HP | 1/4 HP |
Filter Size | 6 - 18" x 24" x 2" |
Fan Diameter | 22 |
ETL Listed | Yes |
Equipment Type | Gas Electric |
Energy Star Rated | Yes |
EER | 12.2 |
Drive Type | Belt |
Cooling Capacity | 146000 |
Condenser Motor RPM | 1100 |
Drain Connections | 2 |
Condenser Motor Type | PSC (Permanent Split Capacitor) |
Condenser Motor Speeds | 1 (Single) |
Cubic Measurement | 243.829700 |
Cycle/Hertz | 60 Hz |
Drain Connection Size | 3/4" |
Parts List
Documents
picture_as_pdf specification sheet
picture_as_pdf warranty document