Robertshaw®

Robertshaw - 780-002 - Lockout Ignition Control Uni-Kit

Item: ROB780002
MFG: 780-002
loading availability
Loading price
/ EA

Description

Lockout Ignition Control Uni-Kit
  • These Kits Have A Lockout Feature To Shut Off All Gas To The Furnace, Should Pilot Ignition Fail To Occur After A Predetermined Time Period.
  • The 780-002 Provides 3 Tries For Ignition, Each Ignition Period Is 90 Seconds Followed By A 6 Minute Time Delay Between Ignition Attempts. After 3 Tries If No Pilot Flame Is Sensed, Unit Goes Into Lockout and Must Be Reset At The Thermostat.
  • Replaces One Rod and/or Two Rod Systems.
  • Reduces Truck Stock Inventory, Saving Space and Money.
  • Includes Vent Damper Adaptor Assembly.
  • Easy-To-Install with Complete In-Depth Installation Instructions.
  • Replaces Robertshaw, Johnson Controls, and Honeywell
Specifications:
  • Input Voltage 24 VAC To 50/60 Hz
  • Transformer 24 VAC / 20 VA
  • Spark Rate 3 To 4 Sparks Per Second
  • Pilot Valve,
  • Main Valve 1 Amp At .5 Pf Combined Load 1.5 At .4 Pf
  • Flame Sense Current .7 MA DC @ 25 °C / 24 VAC
  • Maximum Total Current Load 1.5 Amp
  • Flame Failure Reignition Time .8 Seconds Maximum
  • Thermostat Anticipator Setting .7 Amp
  • Ambient Temperature Rating -40 To 175° (-40 To 80 °C)

California residents: see Proposition 65 Warning

Features and Specification

Weight 0.5
Brand Robertshaw®
Cubic Measurement 0.0174
EAN 0662013633561
Height 4
Length 1.5
Prop 65 No
UOM EA
UPC 662013633561
Width 5
Country of Origin MEX