Heil
Heil - RGS089LDCA0AAA - 7.5 Ton Gas Heating/Electric Cooling Single Package Rooftop Unit R-410A
Item: RGS089LDCA0AAA
MFG: RGS089LDCA0AAA
Description
PACKAGE GAS HEATING/ELECTRIC COOLING, R-410A SINGLE PACKAGE
ROOFTOP 3 THRU 15 TONS (1 & 3 Phase)
BUILT TO LAST, EASY TO INSTALL AND SERVICE
ROOFTOP 3 THRU 15 TONS (1 & 3 Phase)
BUILT TO LAST, EASY TO INSTALL AND SERVICE
- R-410A HFC refrigerant
- ASHRAE 90.1 energy compliant efficiency levels
- Single-stage cooling capacity control on all 036-072 models and the 091,101 and 121 models.
- Two stage cooling capacity control on 090,102,120,150 and 180 models
- Rated in accordance with ARI Standard 210/240 (036-060 sizes) and 340/360 (072-180 sizes)
- Designed in accordance with Underwriters’ Laboratories Standard 1995
- Listed by UL and UL, Canada or ETL and ETL, Canada
- Exclusive non-corrosive composite condensate pan in accordance with ASHRAE 62 Standard, sloping design; side or center drain
- Gas efficiencies up to 82%
- Induced draft combustion
- Redundant gas valve, with 1 or 2 stages of heating
- Pre-painted exterior panels and tested to 500 hours salt spray protection
- Fixed refrigerant metering system
- Fully insulated cabinet
- Exclusive IGC solid-state control for on-board diagnostics with LED error code designation, burner control logic.
- “Low NOx” models available that meet California Air Quality Management NOx requirements and include stainless steel heat exchangers
- Cooling operating range from 40 F up to 115 F.
- Access panels with easy grip handles and no-strip screw feature
- Two-inch disposable return air filters
- Tool-less filter access door
- Standard belt drive, constant torque motor
- Advanced terminal board for simple safety circuit troubleshooting and control box arrangement
- Field Convertible from vertical to horizontal airflow on all models. No special kit required on 036-150 models. Field accessory supply duct kit required for 180 size model only
- Provisions for thru-the-bottom power entry capability
- Single point gas and electric connections
- Full perimeter base rail with built-in rigging adapters and fork truck slots
- Scroll compressors with internal line-break overload protection
- Copper tube, aluminum fin coils
- 24-volt control circuit protected with resettable circuit breaker
- Permanently lubricated evaporator-fan motor
- Permanently lubricated, totally enclosed, shaft down condenser motors
- Low pressure, freeze protection, and high pressure switches
- Exclusive IGC anti-cycle protection for gas heat operation
- Solid-state electronic direct spark ignition system
- Flame roll-out safety protector
- Liquid line filter drier
- 15 Year limited warranty on stainless steel heat exchanger
- 10 Year limited warranty on aluminized heat exchanger
- 5 Year limited warranty on compressor
- 1 Year limited warranty on parts
California residents: see Proposition 65 Warning
Features and Specification
Weight | 810 |
---|---|
AHRI - Usage | Packaged |
Air Flow Direction | Convertible |
Blower Motor HP | 2 9/10 BHP |
Blower Motor RPM | 733-949 |
Blower Motor Speeds | 2 (Two) |
Blower Motor Type | ECM (Electronically Commutated Motor) |
Brand | Heil |
BTU Input | 125000 |
BTU Output | 103000 |
CBU - Compressor Bearing Unit | Yes |
CFM Cooling | 2250 |
Condenser Coil Metering Device | Accutrol - Fixed Metering Device |
Condenser Motor HP | 1/4 HP |
Condenser Motor RPM | 1100 |
Condenser Motor Speeds | 1 (Single) |
Cooling Capacity | 88000 |
Cubic Measurement | 125.3464 |
Cycle/Hertz | 60 Hz |
Drain Connection Quantity | 1 |
Drain Connection Size | 3/4" |
Drive Type | Belt |
EER | 11 |
Energy Star Rated | No |
Equipment Type | Gas Electric |
ETL Listed | Yes |
Evaporator Coil Metering Device | TXV/TEV - Thermostatic Expansion Valve |
Fan Diameter | 22 |
Fuel Type | Natural Gas (Factory Installed) or LP Convertible |
Gas Connection Size | 1/2 |
Gas Connection Type | NPT |
Height | 41.25 |
IEER | 12.7 |
Length | 59.5 |
Locked Rotor Amps (LRA) | 164 |
Number of Fan Blades | 2 |
OPT Code | 1PRGS089LDCA0AAA |
Phase | Three |
Product Family | RGS |
Prop 65 | Yes |
Rated Load Amps (RLA) | 28.8 |
Refrigerant | R-410A |
Sound Level (dBA) | 82 |
Stage | Two |
Thermal Efficiency | 82% |
Tonnage | 7.5 |
UL Listed | Yes |
UOM | EA |
UPC | See Optical |
Voltage | 460 VAC |
Width | 88.125 |
Maximum Overcurrent Protection (MOCP) | 50 |
Condenser Coil Fins per Inch (FPI) | 18 |
Evaporator Coil Fins per Inch (FPI) | 15 |
Compressor Type | Scroll |
Return Air Filter Size (RA) | (4) 16" x 20" x 2 |
Country of Origin | MEX |
Blower Wheel Diameter | 15" |
Blower Wheel Width | 15" |
Parts List
AHRI Matchups
Documents
picture_as_pdf warranty document
picture_as_pdf use & care instructions
picture_as_pdf service manual
picture_as_pdf installation instructions
picture_as_pdf specification sheet